# Fresh Air is Better Air

## Next Steps for the HVAC Industry

The adoption of 2012 IECC and ASHRAE 2013 will increase overall activity in the HVAC industry in all regions, bringing more awareness, public interest, and innovation to the market. Existing challenges and deficiencies with mechanical ventilation systems, especially with air exchange systems, will be a primary area for industry advancement. Specifically, issues associated with static pressure and duct run, over-ventilation, system costs and noise, and challenging climates will be at the forefront.

### Static Pressure and Duct Run

Like many other building components, mechanical ventilation systems must overcome realities of physics. The primary impediment to mechanical air flow is friction. As air moves through a duct it loses pressure and will not flow at the same rate at the end of a duct as it did when leaving the central unit.

Additionally, any kink or curvature in the duct itself will further diminish the air flow rate, making proper installation an important factor in a well-operated ventilation system. Many energy raters will inspect homes to ensure the duct system is free of obstructions caused by angles or ill-positioned duct support systems. The integrity of the entire ventilation system and associated operating costs can be significantly compromised due to incorrectly installed duct-work.

### Over-Ventilation

Primarily a concern for air exchange systems, over-ventilation occurs when a home or building is not tight. The conditioned air supplied to the home can leak out through crevices that were not sealed in the building envelope. This is why mechanical ventilation is an effective strategy when combined with a tight building. Over-ventilation results in wasted air and increased energy costs associated with HVAC.

### System Costs and Noise

HVAC systems are one of the most critical components of home and building design and are one of the most expensive – in both installation and operation. Heating and cooling account for 50% of all home energy needs, making it the leading energy cost for homeowners. The potential for an increased demand on whole-house ventilation will significantly affect the HVAC market. Manufacturers who take advantage of this situation by decreasing costs associated with the design, installation, and repair of HVAC systems will capture a significant portion of the market. In addition, refining HVAC systems to be smoother and quieter will be a major selling point.

### Challenging Climates

A leading impediment to HVAC systems is the condition of the outside air before it is brought in from the outside. Humidity is a major challenge when bringing air inside from outdoors. Additionally, it is typically necessary to condition air through an exchange air system in order to supply cool air during hot months and warm air during winter. The desire for humidity and temperature control of incoming air results in additional costs. By investing in more automation controls, building occupants and homeowners could regulate the operation of ventilation in order to ventilate during periods of lower humidity and appropriate temperatures (i.e. bringing air in at night if cooler air is desired). Evaluating outdoor air conditions prior to ventilating requires simple transducers that can communicate with the HVAC system.

# The Code Factor

Beyond the inherent health needs associated with mechanical ventilation, evolving energy code has forced the need for whole-house mechanical ventilation. With increasing standards for building tightness, the relationship between home tightness and home ventilation can be perplexing. Why bring air inside if the goal is building tightness?

For climate zones 3-8, 2009 IECC required building tightness of < 7 ACH @ 50 pascals. With the 2012 IECC standard this tightness requirement has increased to ≤ 3 ACH @ 50 pascals.

The ventilation implications of such tightness are self evident but are also explained through IRC Section R303.4 which states that whole-house mechanical ventilation is required when the air infiltration for a dwelling unit is < 5 ACH @ 50 pascals. Although IECC does not specifically reference ASHRAE, the commonly accepted requirements for residential ventilation are found in ASHRAE 62.2. Therefore, as the adoption of the 2012 IECC becomes more widespread, and ASHRAE 62.2 remains the industry standard, whole-house mechanical ventilation will become standard for all residential buildings in climate zones 3-8. This has broad implications for the HVAC industry, especially in climates deemed hot and humid that rely predominately on energy recovery ventilation (ERV) systems.

Moving forward, successful integration of 2012 IECC and ASHRAE 2013 will require education for building industry professionals and homeowners/building occupants. If not understood correctly, the relationship between home tightness and home ventilation can be perplexing. Why bring air inside if the goal is building tightness?

In truth, building tightness and ventilation are complementary and both are necessary to achieve energy efficiency and healthy, indoor air. The relationship between building tightness and mechanical ventilation provide occupant control of indoor air and comfort. The variability of outdoor conditions, such as hot, cold, or polluted air, are controlled through mechanically operated ventilation systems that can be used when outdoor air conditions are good and not used when they are undesirable (i.e. high ozone days). Additionally, the use of mechanical ventilation supports energy efficiency because conditioned air has less likelihood of seeping out of the building – reducing total energy costs.

# Controlling the Indoor Environment

People spend nearly 90% of their time inside buildings. This makes the quality of the indoor environment an important pursuit and a significant component of building code. Numerous pollutants exist within homes that can negatively impact indoor air quality and occupant health; proper ventilation is necessary to help diffuse and remove these pollutants.

Some of the most common pollutants are the building and finishing materials used in construction. Many builders are doing a good job of limiting the use of products that contain volatile organic compounds (VOCs). VOC’s are carbon-based compounds that have been used in the construction or chemical composition of many building material products like compressed wood cabinets, paints, glues, adhesives, and carpets.

In addition to VOCs, building pollutants occur from occupant use and behavior. Of critical concern is the potential for carbon monoxide. Garage and combustion appliances are the main sources of carbon monoxide (CO) in homes. Weather stripping the attached garage door and installing an air barrier to the garage walls attached to the house can help keep CO from entering the house through cracks and penetrations. With the release of ASHRAE 62.2-2013, CO alarms are now mandatory for all residential dwellings.

Cleaning products are another pollution source common in homes and buildings. As homes become tighter and tighter to improve energy efficiency and reduce the infiltration of outdoor conditions, mechanical ventilation is increasingly necessary.

Furthermore, education is needed to inform homeowners about indoor pollutants to promote source control strategies. When coupled with proper ventilation, source control goes a long way in better indoor air quality.

# Natural vs. Mechanical and Building Efficiency

Traditionally, building ventilation was achieved through the various crevices and gaps existing in the building envelope. Today, homes are designed to be more "airtight," increasing the need for mechanical ventilation.

To obtain this airtight design, house wraps, differently designed windows and doors, caulks, and other insulating materials are used to create tighter seals for improved energy efficiency. However, these homes and buildings now trap particles and pollutants inside and increase the need to provide mechanical ventilation to replace stale, moist, and polluted air with fresh outside air.

# Problems with Mechanical Ventilation

## Essentials of Mechanical Ventilation for Homeowners/Residents

With the increasing tightness of homes, mechanical ventilation is a necessary feature for building design to ensure acceptable indoor air quality and maintain occupant comfort. However, mechanical ventilation is affected by many factors that determine its efficiency and effectiveness, including building tightness, duct systems, and outside air conditions. Understanding these factors is beneficial for homeowners and residential occupants to maintain a healthy and energy efficient space.

### Why the QuFresh does not violate code for 2009 ICC

This article addresses some common concerns that code officials have when a builder introduces outdoor air into residential dwelling units or is required to by the codes as determined by a municipality. The Eco-Saver mode is only a manual override option for the owner and does not violate the requirements in the code.

# Guide to Home Ventilation & IAQ

The purpose of ventilation is to provide fresh (or at least outdoor) air for comfort and to ensure healthy indoor air quality by diluting contaminants. Currently, a wide range of ventilation technologies is available to provide ventilation in dwellings including both mechanical systems and sustainable technologies.

According to ASHRAE standard 62.2-2004, published by the American Society of Heating, Refrigeration and Air-conditioning Engineers (ASHRAE, 2004), single, detached residential buildings are required to meet a whole house ventilation rate based on the number of bedrooms in the house, the number of occupants, plus an infiltration credit (3 cfm per 100 sq. ft plus 7.5 cfm per additional occupant which includes a 2 cfm per 100 sq. ft allowance for infiltration).

## Mechanical technologies must include:
- Continuous exhaust systems
- Intermittent exhaust systems
- Exhaust with make-up air inlets
- Intermittent or continuous local exhaust with make-up air from inlet in return
- Continuous supply
- Intermittent supply with inlet in return side of HVAC System
- Combined exhaust and supply (Balanced)

### Sustainable technologies:
- Infiltration with operable windows
- Passive Stack Ventilation
- Solar Chimney
- Hybrid Systems

# Whole House Ventilation

Energy-efficient homes (both new and existing) require mechanical ventilation to maintain indoor air quality. There are four basic mechanical whole-house ventilation systems: exhaust, supply, balanced, and energy recovery.

## Exhaust Ventilation Systems

These systems work by depressurizing your home. Exhaust ventilation systems are most appropriate for cold climates.

### Supply Ventilation Systems

These systems use a fan to pressurize your home. Supply ventilation also allows outdoor air introduced into the house to be filtered to remove pollen and dust or dehumidified to provide humidity control.

### Balanced Ventilation Systems

Balanced systems introduce and exhaust approximately equal quantities of fresh outside air and polluted inside air and are appropriate for all climates.

## Review of Ventilation Technologies

The purpose of ventilation is to provide fresh (or at least outdoor) air for comfort and to ensure healthy indoor air quality by diluting contaminants. .

### Mechanical Ventilation Types

There are three types of whole house ventilation strategies: exhaust only, supply only, and balanced.

- **Exhaust only**– Generally the most affordable form of ventilation this strategy is not recommended for many climates due to the resulting negative air pressure. 
- **Supply only**– This strategy pressurizes the home or building by pumping fresh air into the space.
- **Balanced**– These systems neither pressurize or depressurize the home but instead brings in and exhausts the same amount of air through dedicated duct systems.